TY - JOUR
T1 - Bond strength of fiber posts and short fiber-reinforced composite to root canal dentin following cyclic loading*
AU - Nagas, Emre
AU - Cekic-Nagas, Isil
AU - Egilmez, Ferhan
AU - Ergun, Gulfem
AU - Vallittu, Pekka K.
AU - Lassila, Lippo V.J.
N1 - Publisher Copyright:
© 2016 Informa UK Limited, trading as Taylor & Francis Group.
PY - 2017/7/3
Y1 - 2017/7/3
N2 - The aim of this study was to evaluate the effect of cyclic loading on the bond strength of fiber posts and short fiber-reinforced composite (FRC) to root canal. One hundred single-rooted teeth were divided into two groups according to the material used for luting fiber posts: (1) Resin-core material (Gradia Core, GC Corp.) and (2) Short FRC (EverX Posterior, GC Corp.). Then the specimens were randomly assigned into three sub-groups according to the post material and the groups are indicated as follows: (1) Short FRC (EverX Posterior) used instead of post and core, (2) Fiber post (GC post, GC Corp.) cemented with resin-core (Gradia Core), (3) Fiber post (GC post, GC Corp.) cemented with short FRC (EverX Posterior), (4) Experimental fiber post cemented with resin-core (Gradia Core, GC Corp), (5) Experimental fiber post cemented with short FRC (EverX Posterior). Then the specimens were subdivided into a further two groups in accordance with the storage condition (cyclic loading and 24 h water storage-control group) (n = 10/per group). The micropush-out bond strength between root dentin and posts was measured. Data were analyzed using three-way ANOVA and Tukey HSD tests (α = 0.05). Micropush-out bond strength of the posts to dentin was significantly affected by the type of post material (p < 0.05). However, the load cycling and the resin-based luting agent used had no effect on bond strength values (p = 0.706 and p = 0.346, respectively).
AB - The aim of this study was to evaluate the effect of cyclic loading on the bond strength of fiber posts and short fiber-reinforced composite (FRC) to root canal. One hundred single-rooted teeth were divided into two groups according to the material used for luting fiber posts: (1) Resin-core material (Gradia Core, GC Corp.) and (2) Short FRC (EverX Posterior, GC Corp.). Then the specimens were randomly assigned into three sub-groups according to the post material and the groups are indicated as follows: (1) Short FRC (EverX Posterior) used instead of post and core, (2) Fiber post (GC post, GC Corp.) cemented with resin-core (Gradia Core), (3) Fiber post (GC post, GC Corp.) cemented with short FRC (EverX Posterior), (4) Experimental fiber post cemented with resin-core (Gradia Core, GC Corp), (5) Experimental fiber post cemented with short FRC (EverX Posterior). Then the specimens were subdivided into a further two groups in accordance with the storage condition (cyclic loading and 24 h water storage-control group) (n = 10/per group). The micropush-out bond strength between root dentin and posts was measured. Data were analyzed using three-way ANOVA and Tukey HSD tests (α = 0.05). Micropush-out bond strength of the posts to dentin was significantly affected by the type of post material (p < 0.05). However, the load cycling and the resin-based luting agent used had no effect on bond strength values (p = 0.706 and p = 0.346, respectively).
KW - Cyclic loading
KW - fiber post
KW - micropush-out
KW - short fiber-reinforced composite
UR - http://www.scopus.com/inward/record.url?scp=84995633289&partnerID=8YFLogxK
U2 - 10.1080/01694243.2016.1257261
DO - 10.1080/01694243.2016.1257261
M3 - Article
AN - SCOPUS:84995633289
SN - 0169-4243
VL - 31
SP - 1397
EP - 1407
JO - Journal of Adhesion Science and Technology
JF - Journal of Adhesion Science and Technology
IS - 13
ER -