Evaluation of D-dimer levels in patients with prosthetic valve thrombosis: Relationship with thrombus burden and cerebrovascular events

Sinan Cerşit, Sabahattin Gündüz, Emrah Bayam, Ahmet Güner, Semih Kalkan, MacIt Kalçik, Süleyman Karakoyun, Mustafa Ozan Gürsoy, Mahmut Yesin, Özkan Candan, Mehmet Özkan

    Research output: Contribution to journalArticlepeer-review

    4 Citations (Scopus)

    Abstract

    Plasma D-dimer level is an indicator of thrombosis and endogenous fibrinolytic activity. We investigated the association between the D-dimer levels and thrombus burden and cerebrovascular events in patients with obstructive prosthetic valve thrombosis (PVT). This retrospective study included 47 patients with obstructive left-sided PVT and 32 controls in whom PVT was excluded with comprehensive transthoracic and transesophageal echocardiography (TEE). The patient group included 11 aortic, 27 mitral, and 9 aortic and mitral valve PVT patients and the control group included 2 aortic, 25 mitral, and 5 aortic and mitral valve patients. Laboratory analysis including plasma D-dimer levels was performed at the time of admission in all patients. The baseline characteristics were similar between the two groups. The plasma D-dimer levels were significantly higher in patients with obstructive PVT compared with controls [680 (110-3590) vs. 310 (80-380) μg/l; P<0.001]. By multivariate logistic regression analysis high D-dimer level, low-INR value on admission, high NYHA functional class and recent history of cerebrovascular accident (CVA), and transient ischemic attack (TIA) were the independent predictors of obstructive PVT. A plasma D-dimer level of greater than 365μg/l predicted the presence of PVT with a sensitivity of 81% and a specificity of 69% (AUC= 0.781, P<0.001). Plasma D-dimer levels were significantly higher in patients with a recent history of CVA/TIA [2140 (470-2980) vs. 590 (380-830) μg/l; P=0.021]. In addition to the so-called indicators of PVT including subtherapeutic anticoagulation, increased D-Dimer levels may strengthen the suspicion of PVT. Moreover, higher plasma D-dimer levels were associated with higher thrombus burden and higher prevalence of recent CVA/TIA.

    Original languageEnglish
    Pages (from-to)294-299
    Number of pages6
    JournalBlood Coagulation and Fibrinolysis
    Volume29
    Issue number3
    DOIs
    Publication statusPublished - 1 Apr 2018

    Keywords

    • D-dimer
    • cerebrovascular accident
    • prosthetic heart valve
    • thrombosis
    • transesophageal echocardiography
    • transient ischemic attack

    Fingerprint

    Dive into the research topics of 'Evaluation of D-dimer levels in patients with prosthetic valve thrombosis: Relationship with thrombus burden and cerebrovascular events'. Together they form a unique fingerprint.

    Cite this