Single-component orthodontic adhesives: comparison of the clinical and in vitro performance

Ufuk Ok, Sertac Aksakalli, Elif Eren, Nourtzan Kechagia

Research output: Contribution to journalArticlepeer-review

17 Citations (Scopus)

Abstract

Objectives: To investigate the clinical and in vitro performance of single-component orthodontic adhesives under metal brackets. Materials and methods: Bimaxillary orthodontic treatment was required for sixty patients and 60 premolar teeth were divided into three groups (n: 20). The single-component orthodontic adhesives Biofix and GC Ortho Connect (GC) that did not require primers were compared to the control group using Transbond XT, which was applied with a primer. For each patient, total bonding time was measured. The Adhesive Remnant Index (ARI(Bracket)) score was noted over 12 months. In vitro tests were used to evaluate specimens, shear bond strength (SBS), ARI(Bracket), and Enamel Surface Index (ESI). After in vitro debonding, the enamel surface and bracket base were analyzed using scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDX). Results: Clinical failure rate with primer was 9.0%, while it was 8.0 and 10.0 for GC and Biofix, respectively. The mean in vitro SBS values of the Biofix, GC, and Transbond XT groups were 8.21, 8.07, and 7.37 MPa, respectively. There were no statistically differences in clinical failure (p = 0.160) and SBS values (p = 0.158). Mean differences in bond-up time per jaw were 9.65, 10.51, and 11.97 min, which were statistically significant (p = 0.0001). Conclusion: Single-component adhesives had acceptable SBS values and enamel effects according to SEM-EDX analysis. Clinically, bonding failure was not shown statistically inferior to bonding with primer. There was also a significant difference in bond-up times. Clinical relevance: Considering an intensely working clinic with bonding processes for at least two jaws per day, this means a saving of the chair time of 1 patient per week. However, better saliva contamination and moisture control with lack of the primer stage and, thereby, an acceptable bracket failure rate will bring clinically significant results with less chair time for clinicians.

Original languageEnglish
Pages (from-to)3987-3999
Number of pages13
JournalClinical Oral Investigations
Volume25
Issue number6
DOIs
Publication statusPublished - Jun 2021

Keywords

  • Adhesive Remnant Index
  • Enamel Surface Index
  • One-year follow-up
  • Shear bond strength
  • Single-component adhesives
  • Survival rate

Fingerprint

Dive into the research topics of 'Single-component orthodontic adhesives: comparison of the clinical and in vitro performance'. Together they form a unique fingerprint.

Cite this