TY - JOUR
T1 - The evaluation of morphology of renal pelvicalyceal system's and infundibulopelvic anatomy of kidney's lower pole in post-mortem series
AU - Çiçek, R.
AU - Dündar, G.
AU - Gökçen, K.
AU - Gökçe, G.
AU - Gültekin, E. Y.
N1 - Publisher Copyright:
Copyright © 2022 Via Medica
PY - 2022
Y1 - 2022
N2 - Background: Urinary system stones are frequently encountered in the community. Together with technological developments, introduction of new treatment procedures such as extracorporeal shock wave lithotripsy, percutaneous nephrolithotomy and retrograde intrarenal surgery has further reduced morbidity, mortality and hospitalisation time of patients. In order to maximise success and to reduce complications of these procedures, it is necessary to evaluate anatomy and morphological differences of kidney collector system before the procedure. This study was conducted for the purpose of determining the morphology of the kidney collector system and the negative anatomic factors of the lower pole in autopsy cases performed in our institution. Materials and methods: Eighty two kidney units obtained from 41 autopsy cases conducted in Faculty of Medicine Department of Forensic Medicine, Sivas Cumhuriyet University between September 2017 and September 2018 were included in the study. Percentages were found as 78% for intrarenal pelvis, 13.4% for borderline pelvis, 6.1% for extrarenal pelvis and 2.4% for pelvic nonexistence. When pelvicalyceal anatomy was evaluated, percentages were found as 32.9% for bicalyceal, 26.8% for tricalyceal, 20.7% for multicalyceal, and 19.5% for unclassified calyceality. When it was evaluated according to opening of calyces into the renal pelvis based on Sampaio classification, percentages were found as 30.5% for AI, 17.1% for type II, 28% for BI, 18.3% for BII, and 6.1% for unevaluated part. Infundibular lengths of kidney's lower pole were detected as under 3 cm in 39% and over 3 cm in 61% of all cases. Infundibulopelvic angles of kidney's lower pole were measured as under 70o in 42.7% and over 70o in 57.3% of all cases. Results: In our study, there was no statistically significant difference between the right and left kidneys in terms of collecting system morphology and lower pole's negative anatomical factors. Only infundibular length which is one of the collecting system morphology and lower pole's negative anatomical factors were statistically shorter in females than males. There was no difference in terms of other parameters. Conclusions: In conclusion, the findings of this study are largely consistent with the results of similar studies. This reveals that renal collecting system morphology and negative anatomic factors in the lower pole collecting system in human are roughly similar. In clinical practice, pre-treatment computed tomography and, if necessary, magnetic resonance urography evaluation of the lower pole negative anatomic factors may contribute to gain preliminary information about both the clearance of stone fragments especially after shock wave lithotripsy and retrograde intrarenal surgery procedures and perioperative complications proactively.
AB - Background: Urinary system stones are frequently encountered in the community. Together with technological developments, introduction of new treatment procedures such as extracorporeal shock wave lithotripsy, percutaneous nephrolithotomy and retrograde intrarenal surgery has further reduced morbidity, mortality and hospitalisation time of patients. In order to maximise success and to reduce complications of these procedures, it is necessary to evaluate anatomy and morphological differences of kidney collector system before the procedure. This study was conducted for the purpose of determining the morphology of the kidney collector system and the negative anatomic factors of the lower pole in autopsy cases performed in our institution. Materials and methods: Eighty two kidney units obtained from 41 autopsy cases conducted in Faculty of Medicine Department of Forensic Medicine, Sivas Cumhuriyet University between September 2017 and September 2018 were included in the study. Percentages were found as 78% for intrarenal pelvis, 13.4% for borderline pelvis, 6.1% for extrarenal pelvis and 2.4% for pelvic nonexistence. When pelvicalyceal anatomy was evaluated, percentages were found as 32.9% for bicalyceal, 26.8% for tricalyceal, 20.7% for multicalyceal, and 19.5% for unclassified calyceality. When it was evaluated according to opening of calyces into the renal pelvis based on Sampaio classification, percentages were found as 30.5% for AI, 17.1% for type II, 28% for BI, 18.3% for BII, and 6.1% for unevaluated part. Infundibular lengths of kidney's lower pole were detected as under 3 cm in 39% and over 3 cm in 61% of all cases. Infundibulopelvic angles of kidney's lower pole were measured as under 70o in 42.7% and over 70o in 57.3% of all cases. Results: In our study, there was no statistically significant difference between the right and left kidneys in terms of collecting system morphology and lower pole's negative anatomical factors. Only infundibular length which is one of the collecting system morphology and lower pole's negative anatomical factors were statistically shorter in females than males. There was no difference in terms of other parameters. Conclusions: In conclusion, the findings of this study are largely consistent with the results of similar studies. This reveals that renal collecting system morphology and negative anatomic factors in the lower pole collecting system in human are roughly similar. In clinical practice, pre-treatment computed tomography and, if necessary, magnetic resonance urography evaluation of the lower pole negative anatomic factors may contribute to gain preliminary information about both the clearance of stone fragments especially after shock wave lithotripsy and retrograde intrarenal surgery procedures and perioperative complications proactively.
KW - infundibulopelvic anatomy
KW - infundibulopelvic angle
KW - kidney anatomy
KW - kidney morphology
KW - post-mortem morphology
KW - urology
UR - http://www.scopus.com/inward/record.url?scp=85131270021&partnerID=8YFLogxK
U2 - 10.5603/FM.a2021.0041
DO - 10.5603/FM.a2021.0041
M3 - Article
C2 - 33899205
AN - SCOPUS:85131270021
SN - 0015-5659
VL - 81
SP - 350
EP - 358
JO - Folia Morphologica (Poland)
JF - Folia Morphologica (Poland)
IS - 2
ER -